CASE STUDIES:


48" Diameter sewage pump impeller.
The impeller for one of N.Y.C. main sewage pumps was found "Practically Destroyed".

On-site machining of a fan shaft for one of the main ventilating fans
of the N.Y.C. Lincoln Tunnel.
A 5" I.D. double roller bearing of one of the main fans that supplies air to the N.Y.C's Lincoln tunnel failed
On-site machining of the support surface of a "Granulator" for a
sugar refining company.
A sugar refining company in New York had a malfunction with (1) one of its Granulators. In its basic


Patented Mechanical Seals Having "Self-aligning"
Stationary Seats, End Pump Leaks.
A large power plant in N.Y. had a very high maintenance cost with regard to some 20" x 24" Centrifugal
Coupling for 400 H.P. 300 R.P.M. Motor/Reciprocating Compressor.
An old style rubber tire coupling had failed due to age and fatigue. A replacement rubber tire that would fit this particular coupling could not be obtained since the manufacturer was no longer in business.

Coupling for 1500 H.P. Motor Boiler Feed Pump.
The Gear type coupling for one of the main boiler feed pumps driven by a 1500 H.P. / 3600 R.P.M. Motor at a major paper mill upstate N.Y. needed to be serviced at least twice during a one year period.

Training a customer's maintenance crew on the proper and efficient
overhaul of Viking Pumps.
A chemical plant in New Jersey uses several Viking Pumps to handle a very hot and viscous product.

Frontline Industries, Inc. | 990 Chancellor Avenue | Irvington NJ 07111 | 800.890.7325 | e-mail: info@frontlineindustries.com